IEC 62612 PDF

September 12, 2019 posted by

IEC Edition CONSOLIDATED. VERSION. VERSION. CONSOLIDÉE. Self-ballasted LED lamps for general lighting services with supply . IECEE Certification & Testing | IEC Standards | IEC /AMD | General Information. This Pakistan Standard was prepared on the basis of IEC: since IEC Standard have been established in and amendment I was issued in October.

Author: Arashisar Yobei
Country: Dominican Republic
Language: English (Spanish)
Genre: Automotive
Published (Last): 3 July 2012
Pages: 491
PDF File Size: 12.9 Mb
ePub File Size: 1.10 Mb
ISBN: 558-6-90229-185-6
Downloads: 6813
Price: Free* [*Free Regsitration Required]
Uploader: Doujinn

See also the text under Clause 11 with regard to the indicated percentage of tested lamps of a total batch F50 or F10 that may fail the requirements of the test.

Dedicated information on the chosen percentage is to be provided by the manufacturer. Both elements are tested.

IEC System of Conformity Assessment Schemes

This will give additional insight as to the reliability of the measured values. General requirements and tests. The value and the conditions are specified in this standard, or assigned by the uec or responsible iev 3. For dated uec, only the edition cited applies. Unless otherwise specified for a specific purpose by the manufacturer or responsible vendor, lamps shall be operated in free air in a vertical base-up position for all tests including lumen maintenance tests.

Ief the end of these tests a and b the LED lamp shall operate and remain alight for 15 min and show no physical effects of the temperature cycling such as cracks or delaminating of the label. Marking according to one of both columns is required. Reference is made to document CIE All LED lamps in the test sample must pass these post treatment criteria. For that reason this standards relies on approximation methods to determine the expected life L50 or L70 of any self-ballasted LED lamp.

  ADVANCED ENGINEERING MATHEMATICS 10TH EDITION SOLUTIONS MANUAL PDF

Stable operation has been reached when the ied of the LED lamp is not increasing more than 5 K per h. Annex B has been reserved for a description of an improved method as compared to CIE Five such cycles shall be carried out.

It is permitted to download this electronic file, to make a copy and to print out the content for the sole purpose of preparing National Committee positions.

The harmonic content is defined as the R. L70, F50 or L50, F Note Method of measuring the luminous flux of LED lamps is under discussion. In the case of a voltage range, measurements shall be carried out at the mean value. For compliance with EMC requirements reference is made to regional requirements.

A fast initial decrease in lumen output does not automatically imply that a particular LED will not make its rated life.

IEC | IEC Webstore | lighting

The definition under 3. NOTE 2 The actual luminous intensity coupled to a specific beam angle is not an element of this performance standard, but the related luminous flux from which the beam intensity and angle are originated is subject of further testing; via calculation it can be determined whether the rated luminous intensities are realistic within the beam angle specified by the manufacturer.

Additionally, the following references are applicable: NOTE 1 LED lamps have a different end of life characteristic than conventional lamps, because they are not subject to sudden lamp failure but will typically dim over time in a gradual way. Both will not be repeated here.

At eic end of this time, and after cooling down to room temperature, the lamp shall remain alight for at least 15 min. All tests irc be carried out at rated frequency. These performance requirements are additional to the requirements in IEC for self-ballasted LED lamps NOTE 1 safety standard When operated in a luminaire the claimed performance data can deviate from the values established via this standard.

  JIS X 0129 PDF

For normative references, see IEC Recommendations for whole product testing or batch testing are under consideration.

26612 self-ballasted LED-lamp is considered having passed the test when the following criteria have been met: Life is always published in combination with the failure rate see NOTE 4 and 3. For non-professional purposes, column Aand for professional purposes, column B is applicable.

NOTE 2 The built-in electronic 626112, however, may show a sudden end of life failure. B Product datasheets 1 or leaflets x x x c Rated life and the related lumen maintenance factor Lx e Failure rate Fxcorresponding to the rated life f Lumen maintenance category Cat A to E, see Clause Tolerances are based on the CIE MacAdam ellipses as normally applied for compact fluorescent lamps and 622612 discharge lamps.

The actual LED behavior with regard to lumen maintenance may differ considerably per type and per manufacturer. You may not copy or “mirror” the file or printed version of the document, or any part of it, for any other purpose without permission in writing from IEC.

IEC Standard – Home

Comments and observations to the comments were considered at that meeting and are incorporated in the CD.

In addition the following definitions ief given. Lamps which are intended for retrofit purposes shall be equipped with adequate means of cooling.

For relevant standards see Bibliography. For undated references, the latest edition of the referenced document including any amendments applies.